Beauty Machine Cooling Problem Solution

If your beauty machine does not make cooling, please do the testing follow below steps. (Suitable for both diode laser machine and IPL machine)

Below steps suitable for both diode laser machines and IPL machines.

1) Replace the same type of handle to this machine. If you do not have the same type other handle near you, then please proceed to the next step.

2) Check if there is any alarming icon in machine, if machine is alarming, first solve the alarming problem.

3) Adjust the cooling level at 0, 3, and 5 on the working interface, and use multimeter at gear DC 20V to measure the voltage status of the cooling output terminals on the control board.

As shown in the video. (Video is example of cooling level at 5)

When the working interface is set as 0, the cooling output should around 0V.

When the working interface is set as 3, the cooling output should varies from 0V to 12V.

When the working interface is set as 5, the cooling output should stay around 12V.

If the voltage is normal, it means it is TEC cooling pad has problem.

If voltage is not normal, it means it is the control board has problem.

High Quality & Affordable Beauty Laser Manufacturer!

Over 15 Years Field Experience
0
Professional R&D Engineers
0
Exported to 80+ Countries
0
Over 150 Experienced Workers
0
Over 50,000 Happy Clients in Worldwide!
0 +

Stelle Laser is an innovate aesthetic & beauty machine manufacturer in China. We produce and sell Diode laser hair removal machine, IPL photorejuvenation machine, ND Yag Laser tattoo removal and pigment treatment machine, Carbon Peel machine, CO2 Fractional Laser and Multifunctional beauty machines combining above handles.

Contact Us

Get Quotation

Leading China Beauty Laser Factory!